Sports Lighting for Every Venue Type
We've lit facilities at every level of competition. Whatever your venue type, we have a proven system with documented photometric results.
Professional & Semi-Pro Stadiums
IESNA RP-6 Level I — Class IV
Specifications
- Lighting level: 150–200+ fc horizontal illuminance for primary competition areas
- Broadcast standard: CRI ≥ 80, Ra Tv ≥ 65, color temperature 5000–5700K
- Uniformity ratio: ≤ 1.5:1 (max/min) on playing surface
- Vertical illuminance: 75–100 fc for broadcast camera coverage angles
- Individual luminaire addressability for adaptive control
- Spill and glare controls per local ordinance requirements
EcoSport Solution
Our professional stadium LED systems use high-mast arrays with individual luminaire control, delivering the precise uniformity and color rendering required for HD and 4K broadcast production. Each installation includes real-time monitoring, remote management capability, and a 10-year comprehensive warranty — because when the cameras are rolling, downtime is not an option.
Every system is photometrically modeled using AGi32 and DIALux before a single pole goes in the ground, and post-installation measurements are included to verify compliance with your IESNA specification.
Typical applications: NFL, MLS, and minor league football stadiums; professional baseball; arena soccer; multi-use stadium facilities and concert venues requiring full production lighting.
College & University Athletics
IESNA RP-6 Level II
Specifications
- Lighting level: 70–100 fc horizontal illuminance for primary competition areas
- Broadcast often required for football, basketball, and high-profile athletics
- CRI ≥ 80 standard; CRI ≥ 90 broadcast premium option available
- Color temperature: 5000–5700K for broadcast compatibility
- Emergency backup lighting capability for critical events
- Conference-specific documentation and photometric report delivered
EcoSport Solution
College and university athletic departments face the dual challenge of meeting conference broadcast standards while managing capital budgets. Our Level II LED systems deliver the right foot-candle levels and uniformity ratios for conference play and broadcast production — without overbuilding to a professional spec the institution doesn't need.
Multi-pole layouts, flexible zone control, and emergency backup capability are standard. We provide complete conference-spec documentation, permit-ready photometric reports, and coordinate with campus facilities teams throughout the project.
Typical applications: NCAA Division I, II, and III football stadiums; basketball arenas and multi-sport fieldhouses; track and field facilities; baseball and softball stadiums.
High School & Community Sports
IESNA RP-6 Level III
Specifications
- Lighting level: 30–50 fc horizontal illuminance for recreational and scholastic competition
- State athletic association compliance documentation provided
- Spill and glare mitigation for residential and community adjacency
- Simple control interface — operators don't need to be engineers
- Cost-effective pole-mount system layouts optimized for field configuration
- Energy rebate documentation for local utility incentive programs
EcoSport Solution
High school and community venues need the right level of performance at the right investment — not an overspec'd professional system. Our Level III LED solutions deliver reliable, even illumination for scholastic and recreational competition while keeping project costs in line with school district and municipal budgets.
Spill and glare control is engineered from the first photometric model, protecting neighboring residential properties and keeping the project within community standards. Simple preset controls ensure coaches and facility staff can manage the system without a lighting specialist on site.
Typical applications: High school football and track complexes; varsity baseball and softball fields; soccer and lacrosse fields; community park athletic facilities.
Recreation & Multipurpose Indoor
IES RP-6 Indoor Standards
Specifications
- Competition lighting: 50+ fc for scholastic and recreational competition
- Recreational lighting: 30 fc for open gym and casual use
- Uniformity ratio: ≤ 2.0:1 across multipurpose floor areas
- 8 programmable multi-sport presets — adjustable 10–100% output
- Class-leading uniformity for multi-court simultaneous use
- Flicker-free for video streaming and broadcast from portable cameras
EcoSport Solution
Indoor multipurpose facilities need a lighting system as flexible as the space itself. Our linear high-bay LED arrays deliver consistent, competition-grade illumination across the full floor area — with eight programmable presets that let facility managers shift instantly from youth recreation to competitive game night to special events.
Zone-by-zone control means unused areas of the facility can be dimmed independently, reducing energy consumption during partial-use sessions. Real-time energy monitoring gives facility managers visibility into consumption and cost.
Typical applications: Basketball and volleyball gymnasiums; pickleball centers; school fieldhouses and multipurpose gym/auditorium facilities; community recreation centers; YMCA facilities.
Outdoor Courts & Athletic Fields
Sport-Specific Standards — IES RP-6 & USTA / USSSA
Specifications
- Baseball/softball: 30 fc recreational to 150+ fc Class I/II tournament fields
- Soccer: 30 fc recreational to 75 fc competitive match play
- Tennis: 30 fc recreational to 75 fc tournament and broadcast play
- Track and field: 30–50 fc per IES recommendations
- Sport-specific glare-control optics standard on all installations
- AGi32/DIALux photometric modeling included — permit-ready reports delivered
EcoSport Solution
Outdoor field and court lighting is not one-size-fits-all. Baseball infields, soccer pitches, tennis courts, and running tracks each have distinct optical requirements for uniformity, vertical illuminance, and glare control — and we model every one of them before proposing a pole layout or fixture count.
Our sport-specific optic designs direct light precisely where it's needed, minimizing spill to adjacent areas and neighboring properties. Every outdoor installation includes a post-install photometric verification report confirming actual foot-candle levels against the design model.
Typical applications: Baseball and softball complexes (single field to multi-field tournament parks); tennis centers and club facilities; outdoor soccer fields and training complexes; running tracks and combined track/football facilities.
Aquatic Centers
IP65+ Wet Location — USA Swimming & FINA Guidelines
Specifications
- IP65+ wet location rating — full ingress protection for humid, splash, and wash-down environments
- Anti-glare optics required — eliminates glare into swimmers' eyes during starts and turns
- Instant-on operation: full output at the moment of competition start
- Corrosion-resistant housing for chlorine and chemical-heavy environments
- Uniformity designed to eliminate surface reflection interference for officiating
- CRI ≥ 80 for accurate underwater visibility and broadcast quality
EcoSport Solution
Aquatic facilities present unique lighting challenges: harsh chemical environments, anti-glare requirements for competitor safety, and the instant-on demand of competition starts where no warm-up time is acceptable. Our IP65-rated LED systems are designed specifically for aquatic environments — corrosion-resistant housings, sealed optical assemblies, and a 10-year warranty that covers the full system in wet-location conditions.
Anti-glare optic design is engineered from the first photometric model, directing light to the pool surface without creating glare angles into swimmer sight lines during starts or turns. Systems meet USA Swimming and FINA lighting guidelines for sanctioned competition.
Typical applications: Competitive aquatic centers (50m and 25-yard pools); diving facilities; recreational swim clubs and YMCA natatoriums; water polo facilities; indoor and outdoor aquatic complexes.
Ready to Design Your Venue?
Tell us about your facility and our sports lighting engineers will get to work on a custom photometric plan.
Start Your Venue Project